loading...

How to Adjust the XY Gantry

[ Manual N2&N2 Plus - How to Adjust the XY Gantry - V1.0 ]


Preparation:

1. Unload the filament.

2. Move the build plate to center height.

3. Turn off the power.

 

Tools:

①    leveling block

②    2mm hex wrench

  • ③    2.5mm hex wrench


1. Use a 2mm hex wrench to remove all 16 screws on X/Y gantry.

Figure 1 Remove screws on X/Y gantry.

 

2. Use a 2.5mm hex wrench to remove all 8 M3x8 screws on X/Y gantry block.

Figure 2 Remove screws on X/Y gantry block.

 

3. Place the leveling block on the left side of the X axis. Push the extruder head to the left side against the leveling block.

 

4. Use a 2mm hex wrench to tighten all 8 screws shown in the figure below, which retain the rods on the lower position. 

Figure 3 Tighten all 8 screws.

 

5. Take the leveling block out and place it on Y axis. Push the extruder head against it tightly.


Figure 3 Place the leveling block on Y axis.

 

6. Use a 2mm hex wrench to tighten all 8 screws shown in the figure below, which retain those rods on the higher position. 


Figure 4 Tighten all 8 screws.

 

7. Push the extruder to the original position and apply lubricant o all rods. Move the head around to check its motion.

Figure 5 Apply lubricant o all rods.

 

8. Place the extruder in the middle left position and move it in the X direction. If the movement is stable, use a 2.5mm hex wrench to tighten the 4 screws on the left X direction block. Next move it along the X direction, and if it still moves smoothly, use a 2.5mm hex wrench to tighten the 4 screws in the X direction on the right.

Figure 6 Check the movement of the extruder.

 

9. Move the extruder along the bed to check if it moves freely. If not, please re-adjust the extruder according to the steps in this document.


[ Manual N2&N2 Plus - How to Adjust the XY Gantry - V1.0 ]


-END-